If you trying to install a USB device class driver included in Windows, you do not need to download the driver. They are installed automatically. If they are not installed automatically, contact the device manufacturer. For the list of USB device class driver included in Windows, see USB device class drivers included in Windows.


Starting in Windows 10, Usbser.inf was added to the %Systemroot%\INF directory, which loads Usbser.sys as the functional device object (FDO) in the device stack. If your device belongs to the communications and CDC control device class, Usbser.sys is loaded automatically. You do not need to write your own INF to reference the driver. The driver is loaded based on a compatible ID match similar to other USB device class drivers included in Windows.




Cdc serial driver for windows 7 15



Microsoft encourages you to use in-box drivers whenever possible. On mobile editions of Windows, such as Windows 10 Mobile, only drivers that are part of the operating system are loaded. Unlike desktop editions, it is not possible to load a driver through an external driver package. With the new in-box INF, Usbser.sys is automatically loaded if a USB-to-serial device is detected on the mobile device.


In Windows 8.1 and earlier versions of the operating system, Usbser.sys is not automatically loaded when a USB-to-serial device is attached to a computer. To load the driver, you need to write an INF that references the modem INF (mdmcpq.inf) by using the Include directive. The directive is required for instantiating the service, copying inbox binaries, and registering a device interface GUID that applications require to find the device and talk to it. That INF specifies "Usbser" as a lower filter driver in a device stack.


Starting in Windows 10, Usbser.sys supports USB Selective Suspend. It allows the attached USB-to-serial device to enter a low power state when not in use, while the system remains in the S0 state. When communication with the device resumes, the device can leave the suspend state and resume the working state. The feature is disabled by default and can be enabled and configured by setting the IdleUsbSelectiveSuspendPolicy entry under this registry key:


Starting in Windows 10, a Windows app can send requests to Usbser.sys by using the Windows.Devices.SerialCommunication namespace. It defines Windows Runtime classes that can use to communicate with a USB CDC device through a serial port or some abstraction of a serial port. The classes provide functionality to discover such serial device, read and write data, and control serial-specific properties for flow control, such as setting baud rate, signal states.


This example shows how to use the CDC ACM USB class, commonly known as Virtual COM port. After connecting the USB cable, the development kit will enumerate as a COMx port on Windows hosts or as a /dev/ttyACMx device on Linux/Unix hosts. The port can be opened and closed just like a traditional serial port.


DriverGuide maintains an extensive archive of Windows drivers available for free download. We employ a team from around the world which adds hundreds of new drivers to our site every day. How to Install Drivers Once you download your new driver, then you need to install it. To install a driver in Windows, you will need to use a built-in utility called Device Manager. It allows you to see all of the devices recognized by your system, and the drivers associated with them.


Many device drivers are not updated through the Microsoft Windows Update service. If you are having trouble finding the right driver, stop searching and fix driver problems faster with the Automatic Driver Update Utility. Automatic updates could save you hours of time.


The Driver Update Utility automatically finds, downloads and installs the right driver for your hardware and operating system. It will Update all of your drivers in just a few clicks, and even backup your drivers before making any changes.


Many computer problems are caused by missing or outdated device drivers, especially in Windows 11. If your desktop or laptop is running slow, or keeps crashing or hanging, there is a good chance that updating your drivers will fix the problem.


Download this example project onto Denebola RDK. When the kit enumerates, UVC interface automatically binds to UVC driver and will come up as CX3-UVC under 'Imaging devices' section of Device Manager. Whereas, the CDC interface will come up as CX3-UVC under 'Other devices' section of Device Manager.


This document explains the Communications Device Class (CDC) Abstract Control Model (ACM) + Mass Storage (MS) composite Linux gadget driver and how to use it with a Linux host PC and a Windows host PC.


The CDC ACM + Linux gadget MS driver is a USB composite gadget driver which implements the serial communication and mass storage functions. This allows the device to be registered on a host computer as a seral port (e.g. /dev/ttyACM0 or COM1:) and as a USB thumbdrive (e.g. /dev/sdf or E:). The composite driver allows for simultaneoususe of the serial and mass storage functions.


Our experience shows the CDC ACM + MS composite USB driver is not well supported on Windows with this INF file. We have tested with a propretary solutions fromThesycon, with a demo version available at


Once the Linux gadget driver has been installed correctly we just need to mount the SD card on the device in order to get the mass storage device ready. In order to do that we just need to run the following commands on the target device:


When using the device on Windows, you need to use a INF file in order to load the appropriate driver. There is an INI file avaiable (see above), but it didn't workfor use on Windows 7 with a CDC ACM + MS device. Instead we used the proprietarydriver from Thesycon.


Thesycon provides a demo version of the driver[1] that can be installed on Windows.By default it creates a directory on C:\Thesycon\CdcAcm\V1.96.0_Demo\. There isan INI file and a SYS driver in the idisk sub-directory you can use to exchange USB serial datawith the target device.


Replace the USB\VID_VVVV&PID_PPPP string with the corresponding VID and PID. In addition we need to specify the interface on which the serial function is located since it is a composite device.For example, the following uses the Linux Foundation (VID = 0x1D6B) device with a PID = 0x0104(Multifunction Composite Gadget). We assume the serial interface is located in the interface 1, so the piece of code shown above should be replaced by:


Once the edited INF file is read, just plug the device to the Windows host computer. Windowswill try to locate a usable driver. When it asks for the driver just point it to the folder wherethe modified INF file resides and Windows will do the rest.


In order to use the serial function you can install TeraTerm on your Windows machine and launch the TeraTerm application. On first dialog TeraTerm will ask for the connection properties as is shown on figure 1, be sure to select Serial and the port corresponding to your composite device.


A 4GB file was created on the LeopardeBoard using "dd". The file was transmitted from a LeopardBoard to a Ubuntu PC using the USB composite driver. The transmitted file and the file at the LeopardBoard where compared using the sha1sum, both numbers where the same indicating that the USB file transfer didn't corrupted the data.


Make sure you stop any applications running on the target that will interfere with USB serial communication. On target, update inittab and then have init reread the modified file to allow a shell to exist on USB ACM serial port.


Before running the installer, please ensure that the hardware supported by the drivers is not connected. If the hardware is connected when the installer is run, this can prevent the successful installation of the driver files.


c:/ iio_info -sLibrary version: 0.16 (git tag: 5cdeaaa)Compiled with backends: local xml ip usb serialAvailable contexts:0: 0456:b673 (Analog Devices Inc. PlutoSDR (ADALM-PLUTO)), serial=104473222a87000618000600473ed57ae0 [usb:3.8.5]c:\ iio_attr -a -CUsing auto-detected IIO context at URI "usb:3.8.5"IIO context with 8 attributes:local,kernel: 4.6.0-g651ed13usb,idVendor: 0456usb,idProduct: b673usb,release: 2.0usb,vendor: Analog Devices Inc.usb,product: PlutoSDR (ADALM-PLUTO)usb,serial: 104473222a87000618000600473ed57ae0usb,libusb: 1.0.22.11312


I've tried forcing a CDC ACM driver using libwdi, but although the board then appears as a serial device, I can't see any data from the board, so I presume that method is not valid as it may be a composite device and i need a more complex install method (or the official driver)


The HID works OK (as Windows does not need a driver for this), but Windows 7 needs a driver for USB CDC ACM (USB Serial).Actually WIndows 7 has a built in driver for USB CDC ACM if the hardware implements the default protocol (not a special protocol like the FT232 etc use), however Windows 7 will not use its own driver unless you either have a signed driver installer or use something like libwdi)


This is a composite USB device (serial port and HID configuration channel). A composite serial device will only work on Windows XP SP3 and higher. The device will connect and the transmit LED will blink (if configured) but no data is actually sent or received. Read more here and here.


The CDC serial device specification doesn't include CTS or RTS. The firmware in the MCP2200 handles the RTS and CTS signals internally. This means it probably can't reset your Arduino for programming. 2ff7e9595c